NewMar PFM-400 Power Function Manager
 

NewMar PFM-400 Power Function Manager

Price: $1,455.00
Quantity:
Detailed Description
Specifications
NewMar PFM-400 Power Function Manager

NewMar Model: PFM-400

More Information on Newmar PFM-400 Power Function Manager:
NewMar PFM-400 Power Function Manager Brochure

The Newmar PFM-400 Power Function Manager is a system integrating component which converts ordinary power supplies (or Power Modules) into a fully integrated and multifunctional power system. The unit provides for control, monitoring, paralleling and protection of 12, 24 or 48 VDC, positive negative or floating ground power sources.

The NewMar PFM-400 Power Function Manager has a heavy duty (400 amp) parallel tie point bus, digital output voltage and amperage monitoring, system and battery status lights, load distribution circuits, low voltage battery disconnect (ideal for systems with battery back-up) and summary alarm contacts, all combined in a compact, rackmount housing which serves as a master DC power management and distribution center. A high amp rackmount ground/return bus is provided.

The NewMar PFM-400 Power Function Manager may be used for integration, control, monitoring and protection of numerous different types of power sources, such as AC-DC rectifiers, regulated power supplies or DC-DC converters. Note: Installation of Oring diodes recommended for paralleling of most power sources. Oring diode output is standard on PM Series Power Modules.
 

Model

Nominal
Input/Output VDC
Circuit Breaker
Capacity
Digital Meter
Display

Weight
(lbs./kg.)

PFM-400 12, 24, or 48 pos. or neg. ground 5 Volts or Amps 20/9.1

NewMar PFM-400 Power Function Manager Features:
¨ Provides parallel tie point for DC power modules; simplifies wiring
¨ 12, 24 or 48 VDC input/output; can be used with virtually any DC system
¨ Use with positive, negative or floating ground; no need to stock multiple units to meet different
  site requirements
¨ Digital meter displays system voltage or current via selector switch, providing easy on-site
  monitoring of battery and power module output
¨ Status lights indicate system and battery connect/disconnect status, assisting technicians in
  system troubleshooting
¨ Summary alarm contacts (form C) allow remote indication of system status
¨ Low voltage battery disconnect protects batteries in the event of extended AC power loss
¨ Manual battery disconnect switch allows service/replacement of batteries without system shutdown
¨ High current output bus for wiring main system load or for feeding an external distribution panel.
¨ Separate high amp ground bus provided
¨ Up to five optional isolated distribution circuit breakers with ¨TRIP¨ alarm contacts; easy front panel
  plug-in installation (for circuits requiring individual control/protection).

NewMar PFM-400 Power Function Manager Overall Performance
¨ Input/Output: 12, 24 or 48 VDC nominal, positive or negative ground
¨ Maximum Total Current Capacity: 400 amps (max. 6 power supply/modules)
¨ Digital meter accuracy: 1.6% +/- one digit
¨ Circuit breaker voltage rating: 80 VDC (see Options for available amperages)

Protection
¨ Five branch circuit breakers (optional)
¨ Low voltage battery disconnect (See adjacent LVBD Specifications below)

Mechanical/General
¨ Heavy duty plated copper bus bar
¨ Anodized aluminum front/side panels
¨ 19" or 23", 2 RU, flush or 6¨ forward rackmount

Case Size
Inches
Centimeters
Weight
H
W*
D
H
W*
D
lbs
Kg
3.5
17
20.5
13.5
43.2
52.1
20
9.1
*19¨ and 23¨ mounting brackets provided

Indicators/Alarms
¨ System output "OK" L.E.D. indicator
¨ "BATTERY ONLINE" L.E.D. indicator
¨ Digital volt/amp meter (selectable)
¨ LVBD "OPEN" L.E.D. indicator
¨ Form C summary alarm contacts: power module failure, LVBD activation, tripped load breaker

Low Voltage Battery Disconnect Specifications
Factory set actuation voltages:
 
12 VDC
24 VDC
48 VDC
Connect
12.4
24.8
50.0
Disconnect
10.4
20.0
40.0

¨ Min/Max Connect/Disconnect Voltages User adjustable ñ 15%
¨ Max continuous current: 400 amps

Temperature Rating
-40ø C to +60ø C
 
NewMar PFM-400 Power Function Manager Options
¨ Plug-in mid-trip circuit breakers with auxiliary contacts that
activate ¨CHECK SYSTEM¨ indicator and summary alarm contacts.
Available Amperages:
5, 10, 15, 20, 30, 40, 50, 75, 100 (specify model PBA-5,PBA-10, etc.)
¨ Quick connect DC wiring harness for use with Newmar 1 KW Power   
  Modules; QCK-3, CCK-4
¨ Rear Rack Covers: RRC-7-19 or RRC-7-23
¨ Power Modules
¨ Additional Distribution: Model DST-10 (UL) or DST-20A(UL)